Radiscan is designed, developed & manufactured by NDTS ® indigenously to monitor radiation levels where radioactive material or any other source producing radiation is used
All four ranges are calibrated in terms of mR/hr. Latest CMOS circuit design consumes less power. It has been carefully designed to facilitate reading radiation dose. The GM counter detects the single particle of ionizing radiation and produces an audible alarm.
Technical Specifications
- Gas filling : Ne +Halogen
- Cathode material : 446 Stainless Steel
- Maximum length (inch/mm) : 1.34/33.9
- Operating temperature range C : 40 to +50
- Should be able to detect wide range gamma, beta, and X- ray radiation
- mR/hr - (1mR) to 1000 mR/hr
- Sv/hr - 10 to 10000
- mR/hr +/-8% typical +/- 15% max - 1 to 100
- Sv/hr +/-8% typical +/- 15% max - 10 - 10000
- (Referenced to Cs-137)
- Warning indicator: Red LED flashes with each radiation event
- Audio Indicator: Internally mounted beeper (can be switched off for silent operation)
- Saturation: Meter will be saturate above 1000mr/hr
- Power Requirement :Two 9-volt alkaline battery. Battery life is 72 hours at Radiation background
- Temperature Range : -40 °C to 50 °C (14 °F to 122 °F )
- Weight : 400grams with Batteries
- Size : 150mm(L) * 80mm(w) * 45mm(H)